A geothermal system can heat and cool a rural estate for years without a service call, which is exactly why a small leak can go unnoticed. The loop pressure may drift, the antifreeze may weaken, and the entering water temperature may move outside the design range. A loop pressure and antifreeze log makes those slow changes visible. It records the loop field, the fluid mix, the pressure test, and the seasonal performance. The log turns a hidden asset into a managed system.
Key takeaways
- Map every loop, borehole, manifold, and purge point.
- Record the fluid type, the mix ratio, and the freeze point.
- Log the static and operating pressure at each visit.
- Track the entering and leaving water temperatures by season.
- Set a pressure and antifreeze check before every heating season.
Map the loop field and the manifold
Draw the boreholes or the horizontal loops, the header, the manifold, and the mechanical room. Mark each loop with the identifier used at the manifold and the valve tags. Add the borehole depth, the pipe size, and the grout type where the records show them. A loop that is not on the map cannot be isolated or balanced. The drawing should be clear enough for a contractor who did not install the field.
Record the manifold location, the isolation valves, the flow centres, and the purge points. Note the pressure gauge, the expansion tank, and the fill connection. Add the access route for a service truck and the location of the loop field. A manifold buried in a finished wall is a maintenance problem. The record should say so before a repair is needed.
Note the loop field surface, the landscaping, the driveway, and any structure above it. Add the setbacks and the areas that must not be disturbed. A new patio over a horizontal loop can change the heat transfer and the repair access. The record should show the surface use and the restriction.
Photograph the manifold, the gauge, the expansion tank, and the loop field markers. Note the date and the pressure at the time of the photo. A photo of a gauge without a date is weak evidence. The record should make each reading traceable to a visit.
Record the fluid, the mix, and the freeze point
Record the fluid type, the manufacturer, and the concentration. Note whether it is propylene glycol, ethylene glycol, or another approved mix. Add the freeze point and the burst point that the concentration provides. A mix that protects to minus ten degrees may not protect a rural estate in a hard winter. The record should show the actual freeze point, not only the jug label.
Take a sample at the manifold and record the refractive index or the specific gravity. Note the test method, the temperature, and the tester. Add the date and the bottle identifier. A sample drawn from a stagnant port can mislead. The record should show where the sample was taken and how it was handled.
Inspect the fluid colour, clarity, and odour. Note any sediment, oil sheen, or biological growth. Add the filter condition and the last flush. A dark or cloudy fluid can point to corrosion or contamination. The record should connect the visual finding to the chemical result.
Record the top-up volume and the reason for the top-up. Note whether the make-up water was treated and what was added. Add the date and the person who performed the work. A system that needs frequent top-up has a leak or an air problem. The record should show the trend, not only the single event.
Log the pressure and the leak test
Record the static pressure before the pump starts and the operating pressure after it stabilizes. Note the suction and discharge readings and the pressure differential. Add the fluid temperature at the gauge. A pressure that drops overnight is a stronger signal than a pressure that is low on one visit. The record should show the resting and running values side by side.
Perform a pressure hold test when the loop is isolated and record the starting pressure, the hold time, and the final pressure. Note the test medium and the gauge calibration. Add the ambient temperature and any change during the test. A pressure test without a hold time is only a reading. The record should state the pass or fail against a written threshold.
Check the expansion tank charge and the relief valve. Note the pre-charge, the system pressure, and the valve rating. Add the last relief test and any discharge evidence. A failed expansion tank can drive pressure changes that look like a loop leak. The record should separate the tank finding from the loop finding.
Record the flow rate at each loop and the position of the balancing valve. Note the design flow and the measured flow side by side. Add the pump speed and the power draw. A loop with low flow may be airlocked, fouled, or partly closed. The record should show the pattern across loops, not only the total.
Track the temperatures and the performance
Record the entering and leaving water temperature at the heat pump in heating and cooling mode. Note the outdoor temperature, the run time, and the stage. Add the flow rate at the time of the reading. A temperature difference that grows over the season can point to a fouled loop or a low charge. The record should show the trend, not only the design value.
Record the compressor run hours, the auxiliary heat hours, and the energy use where the meter allows. Note the cost and the outdoor design condition. Add the setpoints and the schedule. A system that relies on auxiliary heat more each year is losing capacity. The record should connect the performance to the operating cost.
Check the ground temperature or the loop field temperature where a sensor exists. Note the depth and the time of year. Add the soil type and the moisture condition. A dry summer can change the loop performance in a way that a winter reading will not reveal. The record should show the seasonal range.
Record any short cycling, noise, vibration, or water hammer. Note when it occurs and what changed. Add the pressure and temperature at that moment. A new noise is often the first sign of a pump or a flow problem. The record should capture the condition before it becomes a failure.
Set the seasonal and repair routine
Write a pre-heating-season check that covers the pressure, the antifreeze, the expansion tank, the flow, and the controls. Assign an owner and a date for each step. A check that lives only with the installer will be skipped after the warranty. Keep a copy with the loop drawings and the heat pump manual. The estate manager should be able to see that the work was done.
Write a post-cooling-season check that records the loop temperature, the fluid sample, and any top-up. Note the run hours and the auxiliary heat. Add the findings and the follow-up. A cooling season can hide a slow leak that the heating season will expose. The record should use both seasons.
Set a repair protocol that requires a pressure test, a fluid sample, and a photo before and after any excavation. Note the contractor, the permit, and the restoration. Add the loop identifier and the repair method. A repaired loop without a baseline cannot be compared with the original. The record should protect the field for the next owner.
Review the log with the owner and the geothermal contractor each year. Ask whether the loop still meets the load and whether the antifreeze should be changed. Record the decision and the budget. A system that has never been sampled can still be out of specification. The review should look forward, not only backward.