A wine cellar log that records the temperature, the humidity, the cooling response, and the alarm test, so a collection is protected between service visits. The entry should be dated and signed by the person who checked it. The log is reviewed with the estate team each month. A complete entry lets a new contractor continue without a briefing.
Record the room conditions before touching the collection
Record the temperature and the relative humidity at the same time each day, from the same sensor and the same height. A reading taken beside the door after a delivery is not the room condition. Note the sensor identifier and the last calibration date. The log should show a stable series rather than a single impressive number.
Check the cooling unit, the evaporator, and the drain line for frost, water, or unusual noise. Note the set point and the actual reading side by side. A unit that holds the set point during the day but drifts at night is a failing unit. The log should show the overnight behavior.
Watch the humidity and the cooling response
Record the humidity trend across the week, not only the current percentage. A cellar that swings between dry and damp stresses labels and corks more than a steady room slightly outside the ideal band. Note the humidifier or dehumidifier setting and any water top-up. The log should show the direction of the trend.
Record how long the cooling unit runs to recover after the door is opened. A recovery that lengthens over a month points to a failing compressor, a blocked coil, or a door seal. Note the recovery time and the outdoor temperature. The log should connect the room to the weather.
Test the alarm and the backup
Test the high-temperature and humidity alarm at the agreed interval and record the result. A sensor that never triggers is not protection. Note the test method and the person who confirmed the alert reached the right phone. The log should show the alarm path, not only the sensor.
Record the backup power or the battery status for the monitoring system. A power cut that silences the alarm is the failure the log exists to catch. Note the last battery change and the next test date. The log should show who owns the check.
Review the log with the estate team
Review the month for excursions, recovery times, and alarm tests. Record one action, such as a door seal replacement or a sensor recalibration. A log that is only filed never protects the collection. The review should name the owner and the date.
Keep the sensor calibration and service records with the log. A reading without a calibrated sensor is only a number. Record the last service and the next date. The next review should start from a trustworthy sensor.